Wilmad-LabGlass’s NMR Precision Tubes are manufactured from borosilicate glass that meets the requirement of Type 1 Class A glass from ASTM E438. Precision Tube has 3 fold less paramagnetic contamination comparing to the Economy tube, and can be operated safely at temperature up to 230 ˚C, and within a temperature step of 120 ˚C. Precision tube is rated as hydrolytic class 1, which states that the inner surface is resistant to strong acid and base at ambient temperature. Wilmad-LabGlass is adopting a unique precision shrinking and grinding process to shape the inner surface with maximized filling factor (10% more than Economy tube), and a tight ID and OD tolerance as small as 0.0065 mm. None of our competitors are capable to offer even close products. Each of our individual NMR tubes released into the market has been manufactured in the state-of-art facility in the United States and passed multiple NIST traceable gauge control and optical surface defect checks.
505-PS-7-5 Specifications
MHz Rating:100
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2 ± 0.2
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):76
Camber (microns):51
Pack Size: 5 Tubes
505-PS-8-5Specifications
MHz Rating:100
Length (inch):8
OD (mm):4.9635 ± 0.0065
ID (mm):4.2 ± 0.2
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):76
Camber (microns):51
Pack Size: 5 Tubes
505-PS-9-5 Specifications
MHz Rating:100
Length (inch):9
OD (mm):4.9635 ± 0.0065
ID (mm):4.2 ± 0.2
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):76
Camber (microns):51
Pack Size: 5 Tubes
506-PP-7-5Specifications
MHz Rating:200
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):51
Camber (microns):51
Pack Size: 5 Tubes
506-PP-8-5Specifications
MHz Rating:200
Length (inch):8
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):51
Camber (microns):51
Pack Size: 5 Tubes
507-PP-7-5 Specifications
MHz Rating:300
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):51
Camber (microns):25
Pack Size: 5 Tubes
507-PP-8-5Specifications
MHz Rating:300
Length (inch):8
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):51
Camber (microns):25
Pack Size: 5 Tubes
507-PP-9-5 Specifications
MHz Rating:300
Length (inch):9
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):51
Camber (microns):25
Pack Size: 5 Tubes
526-PP-7-5Specifications
MHz Rating:350
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):51
Camber (microns):13
Pack Size: 5 Tubes
526-PP-8-5Specifications
MHz Rating:350
Length (inch):8
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):51
Camber (microns):13
Pack Size: 5 Tubes
527-PP-7-5Specifications
MHz Rating:400
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):25
Camber (microns):25
Pack Size: 5 Tubes
527-PP-8-5Specifications
MHz Rating:400
Length (inch):8
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):25
Camber (microns):25
Pack Size: 5 Tubes
528-PP-7-5Specifications
MHz Rating:500
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):25
Camber (microns):13
Pack Size: 5 Tubes
528-PP-8-5 Specifications
MHz Rating:500
Length (inch):8
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):25
Camber (microns):13
Pack Size: 5 Tubes
528-PP-9-5Specifications
MHz Rating:500
Length (inch):9
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):25
Camber (microns):13
Pack Size: 5 Tubes
535-PP-7-5Specifications
MHz Rating:600
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):13
Camber (microns):6
Pack Size: 5 Tubes
535-PP-8-5 Specifications
MHz Rating:600
Length (inch):8
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):13
Camber (microns):6
Pack Size: 5 Tubes
535-PP-9-5 Specifications
MHz Rating:600
Length (inch):9
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):13
Camber (microns):6
Pack Size: 5 Tubes
541-PP-7-5 Specifications
MHz Rating:800
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):3.8
Camber (microns):3.8
Pack Size: 5 Tubes
542-PP-7-5Specifications
MHz Rating:1000
Length (inch):7
OD (mm):4.9635 ± 0.0065
ID (mm):4.2065 ± 0.0065
Description:Thin Walled
Wall Thickness (mm):0.38
Concentricity (microns):2.5
Camber (microns):3.8
Pack Size: 5 Tubes
Application Notes
3 mm Economy Material ASTM Type 1 Class A Borosilicate Glass Impact on shimming quality by paramagnetic impurities1 Small (400 ppm Fe2O3) Rapid cooling/heating Yes, within 120 ˚C Max. working temperature 230 ˚C Sample volume reproducibility2 0.5% for sku with “-PP” Averaged Sample Volume within Rf coil 139.0 µl/cm Outer Diameter 4.9635 ± 0.0065 mm Cut-off wavelength 320 nm Compatible with Small Volume Insert Yes except sku with “-PS” Recommended Application Experiments that require critical shimming quality Note 1: Impact on shimming quality varies upon magnetic field strength. Economy tube is recommended for 1D low field experiments. Note 2: Sample volume reproducibility refers to the maximum volume fluctuation when filling different NMR tubes to the same sample height. This number correlates to the reproducibility of time domain signal amplitude between different runs.